Model 90 Low Pressure Selector Relay from Rotork Fairchild

Model 90 Low Pressure Selector Relay from Rotork FairchildModel 90 Low Pressure Selector Relay is designed to select the lower of two signal pressures to provide a continuous output pressure to a control device. The Model 90 is recommended for dead end or low flow service in critical applications such as control loops requiring precise, automatic monitoring of signal pressures.

Features

Model 90 Low Pressure Selector Relay

  • Small, rugged design - suitable for installation where space is limited
  • Soft seat construction assures positive shutoff
  • Low selection differential allows precise control of switching function
  • Fast response - well suited for control in critical loops
  • Automatic switching eliminates manual monitoring of signal pressure

Specifications

Model 90 Low Pressure Selector Specifications

ParameterSpecification
Maximum Signal Pressure200 psig (14.0 BAR, 1400 kPa)
Minimum Switching DifferentialLess than 0.1 psig (0.007 BAR, 0.7 kPa)
Maximum Differential Between Signals100 psig (7.0 BAR, 700 kPa)
Ambient Temperature Range-40 to +200 °F (-40 to +93.3 °C)
Body MaterialAluminum Alloy
Diaphragm MaterialDupont Fairprene-coated fabric
Trim MaterialBrass
Product Codes9002 J5 (general example shown)
Pressure Range Codes00 = Model 90 Low Pressure, 10 = Model 91 High Pressure
Pipe Size2 = 1/4" NPT
OptionsJ = Fluorocarbon Elastomers, U = BSPT (Tapered)
Mounting Bracket KitP/N 09921 (sold separately)

Q & A

Q&A Section with Expand/Collapse Icons

Model 90 Low Pressure Selector Q & A

+What is the M90 relay used for?
The M90 is a Low-Pressure Selector Relay, designed to select the lower of two signal pressures and provide a continuous output pressure to a control device — useful in dead-end or low-flow applications and precise control loops.
+What type of design and construction does M90 have?
M90 features a small, rugged design, ideal for installations where space is limited. It uses a soft-seat construction to assure positive shutoff.
+How sensitive/precise is the M90 in switching pressures?
It has a low selection differential (switching differential < 0.1 psig / 0.007 bar) — enabling precise control when selecting between two signal pressures.
+What is the maximum signal / output pressure M90 can handle?
The maximum signal (or output) pressure is 200 psig (≈ 14.0 bar / 1,400 kPa).
+What connection types are available?
The standard connection is 1/4" NPT (female); a 1/4" BSPT (female) variant is also listed.

Downloads

Downloads

 
You were tireless in your support and it will not be forgotten!
 
When we needed technical assistance and application support, Valin was there for us. Their knowledgeable engineers saved us an invaluable amount of time, helping us get up and running quickly. We are very happy with their services.