M-2300 Series High-Purity Inline Ultrasonic Flow Meter from Malema

M-2300 Series High-Purity Inline Ultrasonic Flow Meter from MalemaThe Malema M-2300 Series High-Purity Inline Ultrasonic Flow Meter delivers precision flow measurement for demanding semiconductor applications.

The M-2300 combines the latest digital signal processing (DSP) and ultrasonic flow sensor technology into a single compact unit. Designed with minimalistic cabling for easy installation. The M-2300 series maximizes space without compromising performance.

The M-2300 Series is engineered with corrosion-resistant wetted parts by incorporating an inline PFA tube. The PFA tube incorporates ultrasonic technology with wedge mounted piezoelectric crystals to ensure accurate flow measurement. The M-2300 has no moving components or mechanical seals providing operators with reliable metering accuracy required in critical processes.

Features

M-2300 Series High-Purity Inline Ultrasonic Flow Meter Features:

  • Sensors and electronics in one compact unit
  • Easy installation with minimized cabling
  • No dead legs or other obstructions
  • Straight flow path with no moving parts
  • Corrosion-resistant with PFA-wetted parts
  • Free from ion/particle contamination
  • Accuracy ±1% Full Scale
  • Repeatability ±0.5% Full Scale
  • Minimal pressure loss

Specifications

M-2300 Series High-Purity Inline Ultrasonic Flow Meter Specifications:


Operation Specifications

Measurable FluidLiquids
Fluid Temperature50°- 140°F (10°- 60°C)
Fluid Pressure0-70 psig
Ambient Temperature32°- 115°F (0°- 46°C)
Process ConnectionPFA Tube End or others*
Enclosure ClassificationIP64
*Consult Malema for any special requirements. 


Material Specifications

Enclosure ClassificationIP64
Optional CableConsult factory for available cable lengths and configurations
Non-Wetted PartsPEEK, PP, SS
Wetted PartsHigh-Purity PFA


Performance Specifications

Tube/End Connections1/4"3/8”1/2”
Standard Full Scale Range3 L/min8 L/min40 L/min
Accuracy±1% Full Scale**±1% Full Scale**±1% Full Scale**
Repeatability± 0.5% Full Scale**± 0.5% Full Scale**± 0.5% Full Scale**
*Custom flow ranges available upon request.
**The accuracy and repeatability specifications for custom flow ranges will always be per the Standard Full Scale Range above.


Electrical Specifications

Output Options AnalogCurrent O/P:
Active: 4-20 mA (Max. Load < 900 Ω)
Passive: 4-20 mA (Max. Load < 1,200 Ω)
Voltage Output: 0-10 V DC (min. load > 10K Ω)
Output Options PulseOpen Collector / Max. 30 V DC, 200 mA max.
Configurable for Low Flow Rate, High Flow Rate, Totalizer Greater Than, Totalizer Less Than, Signal Strength Less, Positive Totalizer Pulse*
Digital InputZeroing – Momentary pull-up to 24 V DC for activation
Power Supply24 V DC ±10%
Power Consumption125 mA
Electromagnetic Compatibility (EMC)EMC Directive 2014/30/EU
Digital CommunicationMODBUS over RS-485
*Pulse frequency configurable up to 1 kHz; Pulse weight configurable from 0.01 mL. 


Connector or Pigtail Cable (Optional) Specification

Pin #Wire ColorFunction
1WhiteSignal OUT (4-20 mA or 0-10 V DC)
2BrownPower IN (+24 V DC)
3GreenRemote Zero IN*
4YellowAlarm or Pulse OUT
5GrayRS-485 A, Data -
6PinkRS-485 B, Data +
7BlueGround (Power and Signal)
8RedNot Used

*Momentary pull-up to 24 V DC
NOTE: Consult the factory for other cable and pin-out options

 

Applications

M-2300 Series High-Purity Inline Ultrasonic Flow Meter Applications:

  • CMP
  • Cooling Systems
  • ElectroChemical Deposition (ECD)
  • Electroless Deposition (ED)
  • Laser Equipment
  • Solar PV Equipment
  • Track Tools
  • Wet Clean
  • Wet Process / Chemical Distribution Systems

Q & A

Q&A Section with Expand/Collapse Icons

M-2300 Series High-Purity Inline Ultrasonic Flow Meter Q & A

+ What does the M-2300 Series measure, and what makes it unique?
The M-2300 Series uses transit-time ultrasonic technology, where two piezoelectric transducers transmit and receive ultrasound signals. The difference in transit times upstream vs. downstream determines fluid velocity—and thus flow rate. It delivers this in a compact, integrated sensor-plus-electronics unit, simplifying installation.
+ What level of accuracy and repeatability does it offer?
It achieves ±1% full-scale accuracy and ±0.5% repeatability, providing precise and consistent performance.
+ What are the construction and wetted materials?
The wetted components use high-purity PFA (Perfluoroalkoxy alkane), ensuring exceptional corrosion resistance and preventing contamination. The straight flow path eliminates dead legs and obstructions.
+ What sizes and connection types are available?
Available in ?″, ?″, and ?″ tube or fitting connections. Custom sizes may be available—consult the factory for details.
+ Which applications are best suited for the M-2300 Series?

Ideal for high-purity semiconductor applications, including CMP, cooling systems, ECD, electroless deposition, laser equipment, solar PV equipment, track tools, wet clean, wet processing, and chemical distribution systems.

Downloads

Download Malema M-2300 Series High-Purity Inline Ultrasonic Flow Meter Series Brochure


Talk to one of our process control experts today at (855) 737-4714 or fill out our online form to learn more.

 
You were tireless in your support and it will not be forgotten!
 
When we needed technical assistance and application support, Valin was there for us. Their knowledgeable engineers saved us an invaluable amount of time, helping us get up and running quickly. We are very happy with their services.